I have a problem with a TX32 module card of a Motorola 64000.
After a reload of all slots the card just can't get in RUN state it just stays in boot mode and then reboot again.
show chassis status command results:
Current Time: 04/05-11:25:21
Running archive: FLASH:6421.srm4
here is the example what I will gonna do.
plan1 CM ip block: 172.16.160.0 /22 CPE ip block: 10.128.0.0 /22
plan2 CM ip block: 172.16.164.0 /22 CPE ip block: 10.128.4.0 /22
plan3 CM ip block: 172.16.168.0 /22 CPE ip block: 10.128.8.0 /22
I used STG to monitor modems in the network, somehow it works on most of the cisco modems I used. But there are modems that i cannot monitor thru STG, I learned that I need to add a specific OID to do that. Does anyone know what OID I should add on the config file? I am using Cisco DPC2320 modem.
Greetings everyone, I'm running 12.2(33) SCG3 on our 7200s and SCG6 on our 10k CMTSs. I know Netflow is not supported with IPv6 on this IOS train. I glanced at the release notes up until SCJ and didn't see any Netflow support for IPv6.
Does anyone know if and when IPv6 Netflow support will be added to IOS?
Does anyone have an idea what the specific formatting is to the OID .1.3.6.1.2.1.10.127.1.1.4.1.7(mib-2.transmission.docsIfMib.docsIfMibObjects.docsIfBaseObjects.docsIfSignalQualityTable.docsIfSignalQualityEntry.docsIfSigQEqualizationData.). And a second question: is this the status of the downstream post equalizer of the CM?
Will it be possible to run Docsis 3.0 and 3.1 Upstreams on the same frequencies?
If it's the same CMTS and the same linecard, the system should be able to manage those D30 and D31 CM.
Based on the timing synchronization should it be possible, would I say.
What do you think?
We have some inter-company arguing going on here about micro-reflections.
Some guys say a higher number is better, some say lower is better, and some say wtf are those, and who cares anyway.
Can someone point me to some relatively simple documentation about this subject that can be spread around to prove which is correct?
I've tried this site: http://www.scte.org/TechnicalColumns/09-11-01%20what%20is%20a%20micro-re...
but met with mostly blank gazes.
I am installing a cmts ubr10k and console the following error appears "% CI-1-TOTALFANFAIL: Total fan tray failure". looking at the fan module has no fault FAN OK light! this green. FAN module model is "UBR10-FAN-ASSY =" and fw is used ubr10k4-k9p6u2-mz.122-33.SCF1.bin
Anybody out there who knows a good cm monitoring tool?
It should monitor every cm and should paint a graph with us-snr, us-pwr(min-max), ds-recv-pwr(min-max) and ds-snr.
This values could be monitored every 5 to 10 minutes.
A second part could be a on demand table with values for every Downstream and every Upstream.
Would be cool, webbased addressed by cm mac address,
thanks