BPI problem on Motorola BSR1000

I have a problem with our BSR1000 which have been working great for 3-4 years now.

After a power failure last week I have some cable modems coming online, but no data are sent through.
The status for the modem on the BSR1000 reads "online(un)".

Manual says:
online(un):
CM registered, but not enabled data. Fail to
verify modem’s identity by BPI module.

Has anybody seen this problem on the BSR? And hopefully has a solution?

Nothing has changed since before the power failure, and the config files are the same.

Thanks,
Jan O Greger

BPI

Hi Jan,
I recommend you setup an sntp server. check the time on your cmts, do a show clock.

Regards
Carl

BPI+ is time dependent

Check the ToD server and the time on the BSR to ensure it's correct -- that's the only time I've seen large scale BPI issues.